还剩30页未读,继续阅读
本资源只提供10页预览,全部文档请下载后查看!喜欢就下载吧,查找使用更方便
文本内容:
锅炉压力容器使用登记管理办法TheManagementforregistrationofoperatingboilerandpressurevesselTheSafetySupervisionBureauofBoilerandPressureVesselundertheStateAdministrationforQualitySupervisionandInspectionandQuarantineContentsTheNoticeontheIssuanceof《Themanagementforregistrationofoperatingboilerandpressurevessel》………………3Themanagementforregistrationofoperatingboilerandpressurevessel………………………4Annex1:《Registrationlicenseforoperatingspecialtypeequipment》pattern…………12Annex2:《Registrycardofboiler》pattern…………………………………………………20Annex3:《Registrycardofpressurevessel》pattern………………………………………23Annex4:installationqualitycertificateofboilerandpressurevesselpattern………………25Annex5:Regulationsincompilingtheregistrationcodeandthenumberofoperationregistrationlicenseofboilerandpressurevessel…………………………………26Annex6:Theclassificationofsafetysituationofthepressurevesselanddescriptionsforit……29Annex7:Certificationforownershiptransferorremovalandreinstallationpattern…………32StateAdministrationforQualitySupervisionandInspectionandQuarantineGZJGNo.207
[2003]TheNoticeontheIssuanceof《Themanagementforregistrationofoperatingboilerandpressurevessel》EachprovinceautonomousregionmunicipalityunderthecentralauthoritycitydirectlyunderstateplanningandtheQualityandTechnologySupervisionBureauofArmyProductionCorpsinXinjiang:Tostrengthentheregistrationmanagementofoperatingboilerandpressurevesselandnormalizetheregistrationofoperationaccordingtotheconcerningstipulationsasregulatedin《SafetySupervisoryRegulationsforspecialtypeequipment》《Themanagementforregistrationofoperatingboilerandpressurevessel》wassetdownbythestateadministrationandshallbeexecutedfromSeptember1st
2003.Nowthedocumentisprintedanddistributedtoyou.Pleasecarryitintoactionearnestly.IncaseanyproblemsshouldoccurduringexecutiontheyshallbereportedtoTheSafetySupervisionBureauofBoilerandPressureVesselundertheStateAdministrationintime.Theoriginaldocument《Managementforregistrationofoperatingboilers》LRGNo.2
[1986]and《Managementforregistrationofoperatingpressurevessel》LBFNo.442
[1993]assetdownbyMinistryofLaborandPersonnelMinistryofLaborshallbeabolishedsimultaneously.StateAdministrationforQualitySupervisionandInspectionandQuarantineofthePeople’sRepublicofChinaJuly14th2003ThemanagementforregistrationofoperatingboilerandpressurevesselChapter1GeneralprinciplesArticle1Inordertostrengthentheregistrationmanagementofoperatingboilerandpressurevesselandnormalizetheregistrationofoperationaccordingtothestipulationsasregulatedin《SafetySupervisoryRegulationsforSpecialTypeEquipment》thisprocedurewasformulated.Article2Registrationproceduresshallbemadeforapplicationoffollowingboilersandpressurevessels:1Theboilerswithinthescopeasregulatedin《SafetyTechnologySupervisoryRegulationsforsteamboiler》《SafetyTechnologySupervisoryRegulationsforHotWaterBoiler》and《SafetyTechnologySupervisoryRegulationsforOrganicheatcarrierboiler》.2Thestationarypressurevesselmovablepressurevesselrailwaytankcarautomobiletankcarandtanktypecontainerandoxygenchamberwithinscopeofregulationsasgivenin《SafetyTechnologySupervisoryRegulationsforPressureVessel》《SafetyTechnologySupervisoryRegulationsforUltraHighPressureVessel》and《SecurityManagementRegulationsforMedicalOxygenChamber》.Article3Theorganizationsandindividualswhichoperateboilerorpressurevesselhereinafterabbreviatedasusershallmakeregistrationforapplicationofboilerandpressurevesselandreceive《Registrationlicenseofoperatingspecialtypeequipment》hereinafterabbreviatedasregistrationlicenseofoperationrefertoAnnex1accordingtothisprocedure.Itisnotpermissibletooperatetheboilersandpressurevesselswithoutmakingregistrationandreceivingtheregistrationlicenseofoperation.Thisprocedureisnotapplicabletoboilersandpressurevesselsusedbymilitaryequipmentnucleardevicesaviationandspacecraftrailroadlocomotiveoffshorefacilitiesandships.Article4Theregistrationlicenseofoperatingboilerandpressurevesselshallbevalidduringthequalifiedperiodregulatedbytheregulartestingforboilerandpressurevessel.Article5TheStateAdministrationforQualitySupervisionandInspectionandQuarantineshalltakechargeofsupervisionandcontrolofregistrationofoperatingboilersandpressurevesselsthroughoutthecountryandlocalqualitytechnicalsupervisiondepartmentabovecountylevelhereinafterabbreviatedasqualitysupervisiondepartmentshalltakechargeofsupervisionandcontrolofregistrationofoperatingboilersandpressurevesselswithintheterritorialdistrict.Thequalitysupervisiondepartmentonprovincelevelorofthecitywithdividingdistrictsshallbetheregistrationorganizationforboilerandpressurevesselapplication.Theregistrationofoperatingpowerstationboilerbelongingtonationallarge-scalecompanyofpowergenerationshallbeproceededbyqualitysupervisiondepartmentonprovincelevelandtheregistrationofoperatingotherboilersandpressurevesselsshallbechargedbyqualitysupervisiondepartmentofthecitywithdividingdistricts.StateandMengleagueofregionlevelandtheregionlevelcitywithoutdividingdistrictsshalltakechargeofregistrationofoperatingboilersandpressurevesselswithintheterritorialdistrictjustlikethecitywithdividingdistricts.Thequalitysupervisiondepartmentofthemunicipalityunderthecentralauthorityshallconsignthequalitysupervisiondepartmentonthelowerleveltotakechargeofregistrationofoperatingboilersandpressureinitsname.Chapter2RegistrationofoperationArticle6Beforeputtingintoapplicationofeachsetofboilerorpressurevesselorwithin30daysafterputtingintoapplicationtheusershallapplytothelocalregistrationorganizationformakingregistrationofoperationandreceivingoftheregistrationlicenseofoperation.Incasetheuserisusingleaseholdboilerorpressurevesseltheunitwithpropertyrightshallapplytothelocalregistrationorganizationwheretheequipmentistobeappliedforlicenseofoperationwhichistobeusedbytheusertogetherwiththeequipment.Article7Forregistrationmanagementofoperationtheusershallprovidetheregistrationorganizationwithdocumentconcernedaccordingtofollowingregulationsforeachsetofboilerorpressurevesselaswellasitssafetyaccessoriessuchasrupturediskofsafetyvalveandemergencycut-offvalveetc.:1Productqualitycertificatedescriptionsforinstallationapplicationandmaintenanceandthesupervisiontestingcertificateformanufactureandinstallationprocedureasrequiredbysafetytechniquespecifications;2Supervisiontestingreportforsafetyperformanceofimportedboilerorpressurevessel;3Installationqualitycertificateforboilerandpressurevesselannex4;4Methodofboilerwatertreatmentandwaterqualityindexes;5Qualityidentificationorproductqualitycertificateandimperativeproductauthenticationcertificateformovingpartandpressureaccessoriesofmobiletypepressurevesselvehicles;6Therulesandregulationsconcernedforsecuritymanagementofboilerandpressurevessel.Article8ThedocumentasrelativetoArticle71and72shallbesufficientforregistrationmanagementofoperatingfollowingboilersandpressurevessels:1Steamboilerwithwatercapacitylessthan50L;2Steamboilerwithratedsteampressurenotexceeding
0.1Mpa;3Hotwaterboilerwithratedoutletwatertemperaturelowerthan120℃andratedthermalpowernothigherthan
2.8MW;4Pressurevesselwhichisaffiliatedtomachineryequipmentandformsacompleteintegritywiththemachineryequipment.Theoperatingregistrationmanagementforsubsidiarysteamwatercylinderinboilerroomshallbemadetogetherwiththeboilerandnoseparatelicenseshallbeissuedforit.Article9Formanagementofregistrationofoperationrequestedbytheuserthe《Boilerregistrycard》or《Pressurevesselregistrycard》hereinafterabbreviatedasregistrycardseeAnnex2andannex3shallbefilledinforeachsetofequipmentandshallbesubmittedtoregistrationorganizationinduplicate.Article10Receivedthedocumentsubmittedbytheuserandtheregistrycardfilledinbytheuserhereinafterabbreviatedasregistrydocumenttheregistrationorganizationshallexaminethemandmaketheregistrationofoperationintimeaccordingtofollowingregulations:1Theexamineshallbemadeonthespotasfarasitispossible.Theregistrationlicenseofoperationshallbeissuedonthespotwhenregistrydocumentconformstotheregulationsinthisprocedure;incaseitdosenotconformtotheregulationsanoticeofrejectshallbeissuedandreasonsforrejectshallbegiveninwrittenform;2Whenitisimpossibletomakeexaminationonthespottheregistrationorganizationshallprovidetheuserwithcredenceforacceptanceoftheregistrydocument.Theusershallreceivetheregistrationlicenseofoperationorrejectinformationwiththeregistrydocumentacceptancecredenceattheinformedtime;3Foroneapplicationwithregistrynumberlessthan10setstheworkofexamineandlicenseissuanceshallbefulfilledorthereasonofrejectinwrittenformshallbegivenwithin5workingdayssincethedatewhenregistrydocumentwasaccepted;foroneapplicationwithregistrynumbermorethan10setsandlessthan50setstheworkofexamineandlicenseissuanceshallbefulfilledorthereasonofrejectinwrittenformshallbegivenwithin15workingdayssincethedatewhenregistrydocumentwasaccepted;foroneapplicationwithregistrynumbermorethan50setstheworkofexamineandlicenseissuanceshallbefulfilledorthereasonofrejectinwrittenformshallbegivenwithin30workingdayssincethedatewhenregistrydocumentwasaccepted;Article11Formanagementofregistrationlicenseofoperationbytheregistrationorganizationtheregistrycodeandthelicensenumbershallbecompiledaccordingto《Regulationsincompilingofregistrycodeandlicensenumberofboilerandpressurevessel》.Formanagementofregistrationlicenseofoperationformobiletypepressurevesselthe“ICcardofmobiletypepressurevessel”whichrecordstheex-plantinformationandoperatingregistrationinformationshallbereleaseatsametime.Article12Whenregistrationorganizationprovidesthelicensetotheuserthedocumentandacopyoffilledregistrycardsubmittedbythelattershallbereturned.Theusershallestablishsafetytechniquearchivesandtheregistrycardandregistrydocumentshallbepreservedproperly.Article13Theregistrycardshallbehungintheboilerroomorfixedonthebodyofpressurevesselwithexceptionofthoseimpossibletobehungorfixedandthenumberoftheregistrationlicenseofoperationshallbesprayedattheremarkablepartoftheboilerorpressurevesselbytheuser.Article14Shouldtheuserusetheboilerorpressurevesselmadebyorganizationswithoutmanufacturelicensetheregistrationorganizationshallnotmakearrangementsforregistrationforit.Chapter3RegistrationofalternationArticle15Incasethesafetyconditionofboilerandpressurevesselischangedortheyshallbeoutofoperationforlongtimeorremovedtoanotherpositionortransferredtoanotherownertheusershallapplytotheregistrationorganizationforregistrationofalternation.Article16Shouldfollowingalternationsoccurtotheboilerorpressurevesseltheusershallapplytotheregistrationorganizationforregistrationofalternationwithconcerningdocumentwithin30dayssincealternation:1Incaseboilerorpressurevesselhasbeenimportantlyrepairedormodifiedorpressurevesselhaschangeditspurposeoroperationmediumthetechnologyfilesdrawingsforrepairingandmodificationaswellasthesupervisiontestingreportoftheimportantrepairormodificationasrelativetotheboilerorpressurevesselshallbesubmitted.2Incasetheclassofsafetyconditionofpressurevesselhasbeenchangedtheregistrycardofthepressurevesselaswellastechnologyfilesandregulartestingreportofthepressurevesselshallbesubmitted.Article17Shouldtheboilerorpressurevesselbeoutofoperationformorethanoneyeartheyshallbesealedupbytheuserandtheusershallapplytotheregistrationorganizationforstopoperatingtheequipmentwithin30dayssincethesealingandreturntheregistrationlicenseofoperationtotheregistrationorganizationforkeeping.Regulartestingshallbeproceededforre-operatingtheequipmentandtheusershallapplytotheregistrationorganizationforstartusingoftheequipmentwithqualifiedregulartestingreportandgetbacktheregistrycardfromthelatter.Article18Whenboilerandpressurevesselaretoberemovedwithintheadministrativeregionoftheregistrationorganizationtheusershallsubmittheregistrydocumentoftheboilerandpressurevesselandtheinstallationsupervisiontestingreporttotheregistrationorganizationafterremovalandbeforeputtingintooperatingtheequipmentforapplicationofregistrationofalternation.Article19Whenboilerandpressurevesselaretoberemovedoutoftheadministrativeregionoftheregistrationorganizationtheusershallapplytotheoriginalregistrationorganizationwithoriginalregistrationlicenseofoperationandregistrycardforcancellation.Theoriginalregistrationorganizationshallmakemarkofcancellationontheregistrycardandsignandissuethe《Identificationforownershiptransferorremovalinstallationofboilerandpressurevessel》totheuserseeAnnex
7.Whenremovalinstallationisfinishedtheusershallwith《Identificationforownershiptransferorremovalinstallationofboilerandpressurevessel》theregistrycardwithcancellationmarkandregistrydocumentoftheboilerandpressurevesselapplytotheregistrationorganizationattheregionwheretheequipmentwasremovedandinstalledbeforeputtingintooperationorwithin30daysafterputtingintooperatingtheequipmentforregistrationofalternationandgetnewregistrycard.Article20Whenboilerandpressurevesselneedtobetransferredtheoriginalusershallmanagecancellationprocedurefortheregistrationlicenseofoperationattheoriginalregistrationorganizationwithregistrationlicenseofoperationregistrycardandtheregulartestingreportwithintheperiodofvalidity.Theoriginalregistrationorganizationshallwriteofftheregistrationlicenseofoperationandmakemarkofcancellationontheregistrycardthenitshallsignandissue《Identificationforownershiptransferorremovalinstallationofboilerandpressurevessel》totheoriginaluser.Article21Theoriginalusershalltransfer《Identificationforownershiptransferorremovalinstallationofboilerandpressurevessel》theregistrycardwithmarkofcancellationallregulartestingreportsandregistrydocumenttonewuseroftheboilerorpressurevessel.Article22Forboilerandpressurevesseltobetransferredtoanotheruserwithoutremovalthenewusershallapplywithalltransferreddocumentstotheoriginalregistrationorganizationforregistrationofalternationandgettheregistrationlicenseofoperationbeforeputtingintooperationorwithin30daysafterputtingintooperatingtheequipment.Thecancellationprocedurefortheregistrationlicenseofoperationmadebytheoriginaluserandtheregistrationofalternationproceededbythenewusermaybeconductedsimultaneouslyattheregistrationorganization.Article23Forboilerandpressurevesselthatshallbetransferredtoanotheruserandshallberemovedandinstalledinanotherplacewithintheadministrativeregionoftheoriginalregistrationorganizationthenewusershallwithalltransferreddocumentsandtheinstallationsupervisiontestingreportafterremovalandreinstallationapplytotheoriginalregistrationorganizationforregistrationofalternationandgettheregistrationlicenseofoperationbeforeputtingintooperationorwithin30daysafterputtingintooperatingtheequipment.Article24Forboilerandpressurevesselthatshallbetransferredtoanotheruserandshallberemovedandinstalledinanotherplaceoutoftheadministrativeregionoftheoriginalregistrationorganizationthenewusershallwithalltransferreddocumentsandtheinstallationsupervisiontestingreportafterremovalandreinstallationapplytotheregistrationorganizationattheregionwheretheequipmentaretoberemovedandinstalledforregistrationofalternationandgettheregistrationlicenseofoperationbeforeputtingintooperationorwithin30daysafterputtingintooperatingtheequipment.Article25Theoriginalregistrationcodeshallbekeptunchangedinregistrationofalternation.Article26TheworktimingformanagementofregistrationofalternationproceededbytheregistrationorganizationshallbesameasregulatedinArticle
10.Article27Foroperatingboilerandpressurevesselincaseoneofthefollowingsituationsoccurapplicationforregistrationofalternationshallnotbepermissible:1Nooperatingregistrationwasmadefortheequipmentinoriginaloperatingplace;2Noregulartestingwasmadefrotheequipmentinoriginaloperatingplaceortheconclusionoftheregulartestingisstoprunning;3Theequipmentisdiscardedasuselessinoriginaloperatingplace;4Operationconditionswaschangedwithoutauthorizationorillegalrepairormodificationhasbeenproceeded;5Withouttechnicaldataandnameplate;6Thereexistsaccidentpotential;7Pressurevesselwithlevelofsafetyconditionofclass45orpressurevesselwhichhasbeenusedformorethan20years.Article28Whenboilerandpressurevesselarediscardedasuselessusershallbesubmittheregistrationlicenseofoperationbacktotheregistrationorganizationforcancellation.Chapter4SupervisionmanagementArticle29Theregistrationorganizationshalltakedifferentwayssuchaspastingorhangingflowchartofregistrationprocedureatofficelocationsprovidingfreeliteralintroductionmaterialorinternetpublicizingetc.toproclaimthemanagementprocedureandrequirementofoperatingregistrationforboilerandpressurevesselsoastofacilitatetheusersforenquiryandawareness.Electronicdeclaringmaybeappliedbyregistrationorganizationswhenconditionsareavailablesoastoenhancetheworkefficiencyandbeinconvenienceofusers.Article30Theregistrationorganizationshallfinishworkofacceptanceexamineregistrationandalternationwithinthetimeasregulatedbythisprocedurethustominimizethetimesofroundtripofusers.Itisnotallowablefortheregistrationorganizationtocreatedifficultiesforusersorpostponetheircaseswithoutproperreasons.Incaseoflargequantityofequipmenttoberegisteredatonetimetheregistrationorganizationmaymanageprocedureofregistrationandlicenseissuanceatthesiteofuser.Article31Theregistrationorganizationshallestablisharchivestokeepregistrycardsandshallinputinformationofregistrycardregistrycodeandnumberofregistrationlicenseofoperationintothedatabankofcomputerintimethustopracticeadynamiccontrol.Article32Theregistrationorganizationshalltransmittheregistrationinformationtoqualitysupervisiondepartmentondistrictorcountylevelwithin5workingdayssincethelicenseissuance.Receivedtheinformationthesupervisiondepartmentondistrictorcountylevelshallproceedsafetysupervisiontotheoperatingthenewlyincreasedboilerandpressurevesselintime.Article33Theregistrationorganizationonhigherlevelshallorganizeselectiveexaminationstotheregistrationworkoftheregistrationorganizationonlowerleveleveryyear.Article34Thetestingorganizationshallmarkthequalificationsymboloftheregulartestandthedateofthenexttestontotheregistrycardafterthetestofequipmentisqualified.Forunqualifiedequipmentthetestingorganizationshallinformtheregistrationorganizationintime.Article35Afterregulartestofpressurevesselthetestingorganizationshalldeterminethelevelofsafetyconditionofpressurevesselaccordingtostipulationsasregulatedin《Classificationofsafetyconditionlevelofpressurevesselanddescriptions》seeAnnex
6.Normallystationarypressurevesselwithsafetyconditionlevelofclass4shallnotbeoperatedanylonger.Incasetheusercannotchangeorrepairitimmediatelytheusershallwithregulartestreportidentificationofsafetylevelclassificationandregistrationlicenseofoperationapplytotheregistrationorganizationfortemporarysupervisoryoperation.Forthosepermittedtobeoperatedundersupervisiontheregistrationorganizationshallmakethenoticeof“temporarysupervisoryoperation”andtimelimitationontotheregistrationlicenseofoperationandtheequipmentshallbechangedorrepairedwithinlimitedtime.Themobiletypepressurevesselwithsafetyconditionlevelofclass4and5orstationarypressurevesselwithsafetyconditionlevelofclass5shallbewrittenoffandshallbediscardedafterdisassembly.Chapter5SupplementarystipulationsArticle36ThepatternoftheregistrycardandregistrationlicenseofoperationshallbedeterminedbytheStateAdministrationforQualitySupervisionandInspectionandQuarantine.TheregistrationlicenseofoperationformobiletypepressurevesselshallbemadebytheStateAdministrationforQualitySupervisionandInspectionandQuarantineaccordingtoregulationsinthismanagement.Otherregistrationlicenseofoperationandregistrycardshallbeprintedbyregistrationorganizationsaccordingtoregulationsinthismanagement.Article37TheSafetySupervisionBureauofBoilerandPressureVesselundertheStateAdministrationforQualitySupervisionandInspectionandQuarantineshalltakechargeofexplanationofthismanagement.Article38ThisprocedureshallbeexecutedfromSeptember1st
2003.Theoriginaldocument《Managementforregistrationofoperatingboilers》issuedbyMinistryofLaborandPersonnelin1986andtheoriginaldocument《Managementforregistrationofoperatingpressurevessel》issuedbyMinistryofLaborin1993shallbeabolishedsimultaneously.Annex1:《Registrationlicenseforoperatingspecialtypeequipment》pattern1-1Coverpageof《Registrationlicenseforoperatingspecialtypeequipment》RegistrationlicenseforoperatingspecialtypeequipmentTheregistrationofoperationforthisequipmentispermissibleaccordingto《Themanagementforregistrationofoperatingboilerandpressurevessel》.Thislicenseshallcontinuetobevalidonlyinthetestingperiodasregulatedbysafetytechniquecodeofboilerandpressurevesselwhenequipmentisqualifiedinthetestandmarkedwithqualificationsymbol.licenseissuanceorganizationsealedwithcachetlicenseissuancedate:yearmonthdaytestqualificationsymbolanddatefornexttestyearmonthyearmonthyearmonthyearmonthyearmonthyearmonthyearmonthyearmonthyearmonthyearmonth1-2AttachedpageforregistrationofoperatingboilerandpressurevesselAttachedpage1forregistrationofoperatingboilerandpressurevesselserialnumberofregistrationlicenseofoperation:__________registrationcode___________operatingunit:______________________internalserialnumberoftheunit:___________categoryofequipment:_______________manufacturelicensenumber:_______________titleortypeofequipment:________________________________________________________manufacturer:_________________________________________________________________1-3Attachedpage1forregistrationofoperatingmobiletypepressurevesselAttachedpageforregistrationofoperatingmobiletypepressurevesselserialnumberofregistrationlicenseofoperation:______internalserialnumberoftheunit:_____operatingunit:______________________registrationcode:_____________________________titleofpressurevessel:___________________________________________________________manufacturerandmanufacturelicensenumber:________________________________________fillingmedium:________________________________________________________________dateofservicestartup:__________________________________________________________Accordingtostipulationsasregulatedin《Themanagementforregistrationofoperatingboilerandpressurevessel》the《Registrationlicenseforoperatingofspecialtypeequipment》formobiletypepressurevesselshallbevalidonlywhenitisusedtogetherwithICcard.Attachedpage2forregistrationofoperatingmobiletypepressurevesselnumberofvehiclenumberoftrailerserialnumberoftanktypecontainerserialnumberofdangerousgoodsformulatedbytheUnitedNationfortanktypecontainercharacteristicofentirevehicletypeorsizeoftanktypecontainerformofstructureunloadingmodeinsulationmodenumberofchassisvehicleframeweightwithoutloadingtotalweightwithfullloadingaccessoriessafetyvalvequantity/typerupturediskquantity/typeemergencycut-offvalvequantity/typelevelmeterquantity/structureanti-bumpingdevicequantityserialnumberoftankbodynameplatecharacteristicoftankbodyvolumeoftankbodyexternaldimensionsoftankbodymaterialoftankbodyinnerandoutercylinderdesignpressuretestpressuremaximumworkingpressuredesigntemperaturemaximumpermissiblefillingquantityorfillingcoefficientfillingmediumpositionofmanholepositionofnameplatecoloroftankbodywallthicknessoftankbodycylinderbodyheadexternalcylinderbodyAttachedpage3forregistrationofoperatingmobiletypepressurevesseldateoftestingtestingorganizationtestingspecieslevelofsafetyconditiondateofnexttesttesterAttachedpage4forregistrationofoperatingmobiletypepressurevesselRecordoftestingforsafetyaccessoryandpressureaccessorydateoftesttestrecordofsafetyvalverecordofchangeofrupturediskemergencycut-offvalvelevelmeterpressuregaugepressurevalveotheraccessoriestesterAttachedpage5forregistrationofoperatingmobiletypepressurevesselRecordoffillingdateoffillingfillingorganizationfillingquantitybeginningandfinishtimeoffillingfillingpersonnelrecheckpersonnel1-4:AttachedpageforregistrationofoperatingoxygenchamberAttachedpageforregistrationofoperatingoxygenchamberserialnumberofregistrationlicenseofoperation:________internalserialnumberoftheunit:_______titleofoxygenchamber:________________________registrationcode:_______________________operatingunit:_____________________________________________________________________manufacturerandmanufacturelicensenumber:___________________________________________registrationnumberofmedicalorganization:_____________________________________________Annex2:《Registrycardofboiler》patternRegistrycardofboilernumberofregistrationlicenseofoperation:_______________registrationcode:loginandregistrationorganizationdateofloginandregistrationloginandregistrationcodeofequipmentupdatingdateinternalserialnumberoftheunitregistrationlicenseofoperationnumberloginandregistrationpersonneloperatingunitorganizationcodeofoperatingunitaddressofoperatingunitprovincecitydistrictcountyzipcodesafetyadministrativedepartmentsafetyadministrativepersonneltelephonenumbertypeofboilersortofboilertypeofboilerroommanufacturerorganizationcodeofmanufacturercountryofmanufacturermanufacturedateex-plantserialnumbersupervisionandtestingunitofproductorganizationcodeofsupervisionandtestingunitinstallationunitorganizationcodeofinstallationunitinstallationcompletiondatedateofservicestartupformofboilerstructuredesignedworkingpressureMPaauthorizedpressureMParatedoutputl/hMWmediumoutlettemperature℃modeofheatingsortoffuelpurposeofboileroperationstatusmodeofburningmodeofwatertreatmentmodeofdeoxygenationmodeofslagtapmodeofdustandfumeremovalnumberofstokerintheunitnumberofwaterqualitycontrolpersonnelmainsafetyaccessoriesandaffiliatedequipmentwatertreatmentequipmenttitletypespecificationquantitymanufacturertestunitcodeoftestunitdateoftestsortoftestmainproblemstestconclusionserialnumberofreportdateofnexttestsortofemergencyemergencyoccurrencedateemergencydisposalmodeofequipmentalternationequipmentalternationitemdateofequipmentalternationalternationexecutingunitorganizationcodeofthealternationexecutingunitRegistrycardofboilerattachedpageforpowerstationboilermaximumcontinuousevaporationquantityl/hreheatsteamflowl/hworkingpressureofboilercylinderMPasuperheateroutletpressureMPareheaterinletpressureMPareheateroutletpressureMPafeedwatertemperature℃superheateroutlettemperature℃reheaterinlettemperature℃reheateroutlettemperature℃startingpressureofconcurrentboilerMPastartingflowofconcurrentboilerl/hmodeofwatercirculationlayoutoutofburnervolatilecomponentofcombustibleindesignedfuelcalorificvalueatlowpositionofdesignedas-firedbasismodeofrechargewatertreatmentmodeoftemperatureconditioningforsuperheatedsteammodeoftemperatureconditioningforreheatedsteammodeofboilerwater/steamseparationothersituations:Registrycardofboilerbasicinformationnumberofregistrationlicenseofoperation:_______________registrationcode:_____________operatingunitaddressindetailzipcodeprovincewheretheoperatingunitislocatedcitywheretheoperatingunitislocateddistrictorcountywheretheoperatingunitislocatedlegalrepresentativetelephoneortelephoneexchangeE-MailfaxprincipalinchargetelephoneoftheprincipalinchargeundertakertelephoneoftheundertakermobiletelephoneorpagerdateoffillinginthetableremarksAnnex3:《Registrycardofpressurevessel》patternRegistrycardofpressurevesselnumberofregistrationlicenseofoperation:_______________registrationcode:_____________loginandregistrationorganizationdateofloginandregistrationregistrationcodeofequipmentofupdatinginternalserialnumberoftheunitserialnumberoftheregistrationlicenseofoperationloginandregistrationpersonneloperatingunitorganizationcodeoftheoperatingunitaddressoftheoperatingunitprovincecitydistrictcountyzipcodesafetycontroldepartmentsafetycontrolpersonneltelephonetitleofvesselsortofvesselclassificationofvesseldesignunitorganizationcodeofdesignunitmanufacturerorganizationcodeofmanufacturercountryofmanufacturermanufacturedateex-plantserialnumbersupervisionandtestingunitofproductorganizationcodeofsupervisionandtestingunitofproductinstallationunitorganizationcodeofinstallationunitinstallationcompletiondatedateofservicestartupworkshoporsubsidiaryofafactoryinnerdiameterofvesselmmmaterialofthecylindricalbodymaterialofendhoodmaterialofinnerliningmaterialofjacketthicknessofthecylindricalbodythicknessofendhoodmmthicknessofinnerliningmmthicknessofjacketvolumeofvesselm3heightlengthofvesselmmweightofshellweightofinternalcomponentkgweightofmediumfillingkgthermalinsulationavailableornotdesignpressureofshellsideMPadesigntemperatureofshellside℃maximumpressureofshellsidedesignpressureoftubesideMPaMPadesigntemperatureoftubeside℃maximumpressureoftubesideMPadesignpressureofjacketMPadesigntemperatureofjacket℃maximumpressureofjacketshellsidemediumtubesidemediumjacketmediumilluminationofoxygenchambermotorofairconditionerinoxygenchambermodeofoxygentestingforoxygenchamberlicensenumberoftankcarformofstructureoftankcarnumberofundercarriageoftankcarpropertyownercodeofpropertyownersafetyaccessoriesandconcerningdevicestitletypespecificationquantitymanufacturertestunitcodeoftestunitdateoftestsortoftestmainproblemstestconclusionserialnumberofreportdateofnexttestsortofemergencyemergencyoccurrencedateemergencydisposalmodeofequipmentalternationequipmentalternationitemdateofequipmentalternationalternationexecutingunitorganizationcodeofthealternationexecutingunitRegistrycardofpressurevesselbasicinformationnumberofregistrationlicenseofoperation:_______________registrationcode:_____________operatingunitaddressindetailzipcodeprovincewheretheoperatingunitislocatedcitywheretheoperatingunitislocateddistrictorcountywheretheoperatingunitislocatedlegalrepresentativetelephoneortelephoneexchangeE-MailfaxprincipalinchargetelephoneoftheprincipalinchargeundertakertelephoneoftheundertakermobiletelephoneorpagerdateoffillinginthetableremarksAnnex4:installationqualitycertificateofboilerandpressurevesselpatternInstallationqualitycertificateofboilerandpressurevesseloperatingunitofboilerandpressure:________________________________________________titlesortandtypeofboilerandpressurevessel:________________________________________ex-plantserialnumberofproduct:______________internalserialnumberoftheunit:__________addresswhereboilerandpressurevesselareinstalled:__________________________________installationlicensenumber:_________________________________________________________Thissetofboilerpressurevesselwasinstalledbyourinstallationunit.Thiscertificateistoprovethattheinstallationqualityconformstothestipulationsasregulatedbysafetytechniquespecifications.officialsealoftheinstallationunitdate:yearmonthdaytitleoftheinstallationunit:________________________________________address:______________________telephone:_________________________legalrepresentativeoftheunitsealing:______________________________technicalprincipalsealing:________________________________________Annex5:Regulationsincompilingtheregistrationcodeandthenumberofregistrationlicenseofoperationboilerandpressurevessel
1.RegistrationcodeRegistrationcodeshallbecompiledbythesafetysupervisionorganizationwhichtakeschargeofregistrationofrunningequipmentanditservesasasortofpermanentcodewhichisdistributedinfirsttimehandlingofregistrationofoperatingtheequipment.Thecodeofonesetofequipmentshallkeepitsuniquenessduringthecourseofoperationtestingrepairingmodificationremovingandinstallationtillitisdiscardedinspiteofchangeofowneroperatingspotandperformance.Registrationcodeiscomposedbyequipmentclassificationcodeadministrativedivisioncodecodeofloginyearandcodeofsequencetotally20digits.********************codeofsequencecodeofregistrationyearadministrativedivisioncodeequipmentclassificationcodeEquipmentclassificationcodingtableequipmentclassificationcodingboiler1000steamboiler1100powerstationboiler1110industrialboiler1120lifeboiler1130hotwaterboiler1200pressuredhotwaterboiler1210organicheatcarrierboiler1300pressurevessel2000stationarypressurevessel2100reactionvessel2110heatexchangingvessel2120separatingvessel2130storagevessel2140orbicularstoragetank2150deepcoolingvessel2160mobiletypepressurevessel2200ailwaytankcar2210automobiletankcar2220tanktypecontainer2230oxygenchamber2400Description:Forequipmentclassificationcodetheequipmentclassificationcodingtablemaybereferredto:Theadministrativedivisioncodeisindicatedby6digitArabicnumerals.TheclassificationshallbeproceededaccordingtotheadministrativecodeoftheregionwhereequipmentregistrationorganizationislocatedandGB/T2260《TheAdministrativeCodeofthePeople’sRepublicofChina》shallbereferredto;thecodeofregistryyearisindicatedby6digitArabicnumeralsanditisdescribedbyyearandmonthoftheregistrationamongwhich“year”isindicatedby4digitofArabicnumerals“month”isindicatedby2digitArabicnumeralsanda“0”istobeaddedbeforethoseonedigitmonths;generallycodeofsequenceisindicatedby4digitArabicnumeralsandshallbearrangedfrom“0001”to“9999”inthesequenceofsamesortofequipmentregisteredinsamemonth.Incasethenumberofequipmentregisteredinonemonthexceeds9999thefirstdigitmaybecompiledasEnglishletter“A”.Iftheregisteredsequencenumberreaches10002itshallbeindicatedas“A002”andwhenthenumberexceeds“A999”“B”maybeusedinsteadof“A”andtherestmaybededucedbyanalogy.Forexample:certainunitcomestotheboilerandpressurevesselsafetysupervisionorganizationinFengtaidistrictBeijingtomakeregistrationprocedureforasetofhotwaterboiler.Theorganizationhashandledregistrationprocedurefor235setsofhotwaterboilerinMaysothecodeofthissetofequipmentshouldbe:1200110106199905023620digits
2.NumberofregistrationlicenseofoperationforboilerandpressurevesselThenumberofregistrationlicenseofoperationforboilerandpressurevesselshallbecompiledbythesafetysupervisionorganizationondistrictorcitylevelwheretherunningequipmentislocatedwhentheregistrationlicenseofoperatingtheboilerandpressurevesselisissuedbytheorganizationandtheoperatingunitshallhangthisnumberinsidetheboilerroomorsprayitattheconspicuouspositionofthepressurevessel.Thenumberofregistrationlicenseofoperationiscomposedbyfeaturecodemaybeomittedaddresscodeandsequencecode.*************sequencecodeaddresscodefeaturecodeDescription:FeaturecodeiscomposedbyaChinesecharacteraonedigitArabicnumeralandtwodigitEnglishletters.ThefirstChinesecharactershallbe“Guo”or“Rong”;theseconddigitofArabicnumeralrepresentssortofpressurevessel;thethirddigitofEnglishletterrepresentspressureclassofthepressurevesselanditmaybeseparatelyshownasultrahighpressureUhighpressureHmediumpressureMlowpressureL:thefourthdigitEnglishletterrepresentspurposeofthepressurevesselanditmaybeseparatelyshownasreactionvesselRheatexchangevesselEseparationvesselSstoragevesselCorbicularvesselBmedicaloxygenchamberHrailwaytankcarTautomobiletankcarAtanktypecontainerVtheonedigitArabicnumeralandtwodigitsofEnglishletteraftertheChinesecharactermaybeomittedforboiler.AddresscodeiscomposedbyaChineseCharacterand2digitsofEnglishletterorArabicnumerals.ThefirstChinesecharactershallbeabbreviationforeachprovinceautonomousregionormunicipalitydirectlyunderthecentralgovernment;theseconddigitofEnglishletterrepresentseachdistrictorcityinaprovinceshallbedeterminedbyeachprovince;forthethirddigitwhenaEnglishletterisuseditshallrepresentacitycontrolledcountyoralargescalecombinedenterprisewhenanArabicnumeralisuseditshallrepresentacitycontrolledboroughshallbedeterminedbyeachprovince.Generallycodeofsequenceisindicatedby4digitArabicnumeralsandshallbearrangedfrom“0001”to“9999”inthesequenceofboilersandpressurevesselsregisteredinsamecountyborough.Incasethenumberofequipmentofsamesortregisteredexceeds9999thefirstdigitmaybecompiledasEnglishletter“A”.Iftheregisteredsequencenumberreaches10002itshallbeindicatedas“A002”andwhenthenumberexceeds“A999”“B”maybeusedinsteadof“A”andtherestmaybededucedbyanalogy.Forexample:CertainunitinHepingboroughShenyangLiaoningprovincecomestotheboilerandpressurevesselsafetysupervisionorganizationinShenyangLiaoningprovincetomakeregistrationprocedureforasetofhotwaterboiler.Thesequencenumberoftheequipmentis“3421”asarrangedinthesequenceorderofboilersinHepingboroughandtheregistrationlicenseofoperationnumberoftheequipmentasissuedbytheorganizationshouldbe:“GuoliaoA13412”CertainunitinXinminShenyangLiaoningprovincecomestotheboilerandpressurevesselsafetysupervisionorganizationinShenyangLiaoningprovincetomakeregistrationprocedureforasetofstoragetankcontainingliquefiedpetroleumgas.Thesequencenumberoftheequipmentis“8923”asarrangedinthesequenceorderofpressurevesselsinXinminandtheregistrationlicenseofoperationnumberoftheequipmentasissuedbytheorganizationshouldbe:“Rong3MCLiaoAA8923”Annex6:TheclassificationofsafetysituationofthepressurevesselanddescriptionsforitInaccordancewithsafetysituationsofthepressurevesselnewpressurevesselsaredividedintothreelevels:class12and
3.Therunningpressurevesselsaredividedintofourlevels:class234and
5.Theprinciplesfordivisionofeachlevelaregivenbelow:Class1:Theex-planttechnicaldataofpressurevesseliscomplete;thedesignandmanufacturequalityconformstotheconcerningcodeandstandard;theequipmentcanbesafelyoperatedunderdesignconditionsinthestipulatedregulartestingperiod.Class2:a.Newpressurevessel:Theex-planttechnicaldataofpressurevesseliscomplete;thedesignandmanufacturequalityconformstotheconcerningcodeandstandardinthemainbutthereexistcertaindefectsthatdonotjeopardizesafetybutnoteasytobecorrectedandwhenproductleftfactorythedefectswereacceptedbydesignunitoperatingunitandthesafetyandsupervisionorganizationinchargeoftheregioninwhichtheoperatingunitislocated;theequipmentcanbesafelyoperatedunderdesignconditionsinthestipulatedregulartestingperiod.b.Runningpressurevessel:Thetechnicaldataofpressurevesselisbasicallycomplete;thedesignandmanufacturequalityconformstotheconcerningcodeandstandardinthemainaccordingtothetestreportthereexistcertaingeneraldefectsthatdonotjeopardizesafetybutnoteasytoberepaired;theequipmentcanbesafelyoperatedunderdesignconditionsinthestipulatedregulartestingperiod.Class3:a.Newpressurevessel:Theex-planttechnicaldataofpressurevesselisbasicallycomplete;mainbodymaterialstrengthandstructureconformtotheconcerningcodeandstandardinthemainbutcertainproblemsordefectsthatdonotconformtothecodeandstandardoccurredduringmanufactureoftheequipmentbutwhenproductleftfactorythedefectswereacceptedbydesignunitoperatingunitandthesafetyandsupervisionorganizationinchargeoftheregioninwhichtheoperatingunitislocated;theequipmentcanbesafelyoperatedunderdesignconditionsinthestipulatedregulartestingperiod.b.Runningpressurevessel:Technicaldataisnotcomplete;mainbodymaterialstrengthandstructureconformtotheconcerningcodeandstandardinthemainbutcertainproblemsordefectsthatdonotconformtothecodeandstandardoccurredduringmanufactureoftheequipment;thevolumeconcerneddefectisexistedwiththeweldseam.Accordingtothetestreportdefectdevelopmentorenlargingwasnotfoundanditwasconfirmedbythetestreportthattheequipmentmaybesafelyoperatedunderregulatedoperationcondition.Class4:Mainbodymaterialdoesnotconformtotheregulationsconcernedorthematerialisuncertainorthematerialthouselectionwasrighttendstogetaged;thereexistsratherseriousdefectsthatdoesnotconformtothecodeandstandardconcernedwiththemainstructurethestrengthviainspectionmaystillmeettherequirement;lineardefectexistswithweldingquality;accordingtothetestreportdefectdevelopmentorenlargingduetoapplicationfactorwasnotfound;defectssuchascorrosionwearingdamageanddeformationoccurredduringoperationandthetestreportconfirmsthattheequipmentcannotbeoperatedsafelyunderregulatedoperatingconditionorwithinnormaltestingperiod.Relativemeasuresmustbetakentorepairordisposewiththeequipmentthustoincreaseitsclassofsafetysituationotherwisetheequipmentcanonlybeappliedforshorttimeundersupervisionandcontrolandunderrestrictiveconditions.Class5:Thepressurevesselmadebytheenterprisewithoutmanufacturelicenseorbytheenterprisewhichcannottestifytheoriginalmanufacturerwaswiththelicense;theequipmentwithseriousdefectwhichcannotberepairedordoesnotworthrepairingorsafetyoperationstillcannotbeensuredafterrepairing;thea.m.equipmentshallbejudgedasuselessandshallnotcontinuetobeappliedasequipmentoperatedwithpressure.Notes:
1.Thedefectasdescribedinclassofsafetysituationshallbethefinallyexistedstatewhilethepressurevesselwasmade.Incasethedefecthasbeenremovedthenthestateafterremovalshallbethebasisindeterminingthesafetysituationclassofthepressurevessel.
2.Ifthetechnicaldataisincompleteaccordingtotheregulationconcernedtechnicaldatashallbemadeupbyoriginalmanufacturerorbytestingorganizationaftertestingverificationandwithconclusiondrawninthetestreportandinthiscasethetechnicaldatamaybeacceptedascomplete.Incaseitcannotbedeterminedwhethertheoriginalmanufacturingunitwasqualifiedofmanufacturingtomakeupthetechnicaldatabytestingverificationshallnotbepermissible.
3.Forproblemsanddefectsasdescribedinclassofsafetysituationsolongasthemostseriousoneamongthemisconfirmedtheclassofsafetysituationmaybedeterminedaccordingtoitscharacteristics.Annex7:CertificationforownershiptransferorremovalandreinstallationpatternCertificationforownershiptransferorremovalandreinstallationregistrationcode:originalnumberofregistrationlicenseofoperation:titleofboilerorpressurevessel:manufactureunit:serialnumberofmanufacture:dateofmanufacture:titleoforiginaloperatingunit:dateofissuanceoforiginalregistrationlicenseofoperation:dateofcancellationoforiginalregistrationlicenseofoperation:levelofsafetysituationofpressurevessel:Beforeownershiptransferorremovalreinstallationoftheboilerorpressurevesselregulartestingshallbeproceeded.Beforeputtingintooperatingthetransferredorremovedandreinstalledboilerofpressurevesseltheoperatingunitshallapplytothesafetysupervisionorganizationwheretheunitislocatedforrenewingofmanagementofoperatingregistrationprocedure.originaloperatingregistrationorganizationofficialsealyearmonthday本英文版为内部资料,仅供参考,以中文版为准TheChineseversionofstandardshasprecedencetotheirEnglishtranslationswhichareonlyforinternalreference.PAGE—3—。