还剩3页未读,继续阅读
文本内容:
PrefunctionalChecklistProjectSH147LEEDCommissioningPC-ChillerorHEATPUMP(冷水机组或热泵)ID#,s(机组编号)Submittal/ApprovalsSubmittal.Theaboveequipmentandsystemsintegraltothemarecompleteandreadyforfunctionaltesting.Thechecklistitemsarecompleteandhavebeencheckedoffonlybypartieshavingdirectknowledgeof【heeventasmarkedbelowrespectivetoeachresponsiblecontractor.Thisprefunctionalchecklistissubmittedforapprovalsubjecttoanattachedlistofoutstandingitemsyettobecompleted.AStatementofCorrectionwillbesubmitteduponcompletionofanyoutstandingareas.Noneoftheoutstandingitemsprecludesafeandreliablefunctionaltestsbeingperformed.Listattached.提交以上设备和相关系统己经安装完毕并具备功能性调试的条件本检查清单已经完成并由以下相关专业人员复核GeneralContractor(总承包商签字)Date(日期)Prefunctionalchecklistitemsaretobecompletedaspartofstartupinitialcheckoutpreparatorytofunctionaltesting.(本功能与调试检查清单是设备功能调试准备工作的一部分)Thischecklistdoesnottaketheplaceofthemanufacturersrecommendedcheckoutandstartupproceduresorreport.(本检查清单不能替代设备供应商自己的检查和试车程序)Items(hatdonotapplyshallbenotedwith(hereasonsonthisform(N/A=notapplicable.BO=byothers).(本检查清单中不适用的项目应该明确注明原因,N/A为不适用,BO为由其他完成)Ifthisformisnotusedfordocumentingoneofsimilarrigorshallbeused.(如果不使用本表格,可以用具有相似要求的表格替代)Contractorsassignedresponsibilityforsectionsofthechecklistshallberesponsibletoseethatchecklistitemsbytheirsubcontractorsarccompletedandcheckedoff.(分项系统的承包商应负责对其分包的部分工作进行检查并复核清单中的内容)Approvals.Thisfilled-outchecklisthasbeenreviewedby批准本清单已经经过如下人员审核LEEDCommissioningAuthority(调试主管顾问)Date(H期)OwnersRepresentative(业主代表)Dale(R期)Requesteddocumentationsubmitted(需要提交的资料)CheckifOkay.Entercommentornotenumberifdeficient.(符合打J不符合请说明).•Documentationcompleteaspercontractdocumentsforgiventrade•.…YESNO(文件材料按照合同要求完成)Modelverification(设备型号校核)1=asspecified2=assubmitted3=asinstalled.CheckifOkay.Enternotenumberifdeficient.1=与图纸相符,2=与提交资料相符,3=与实际安装相符(符合打“J”不符合请说明)•TheequipmentinstalledmatchesthespecificationsforgiventradeYESNO(安装的设备与设计说明相符)InstallationChecks(安装核查)CheckifOkay.Entercommentornotenumberifdeficient.(符合打“J”不符合请说明)•ThechecklistitemsofPart4areallsuccessfullycompletedforgiventrade.YESNO核查表的第四部分已经完成OperationalChecks运行核查Theseaugmentmfrslist.Thisisnotthefunctionalperformancetesting.CheckifOkay.Entercommentornotenumberifdeficient.符合打J”不符合请说明•ThechecklistitemsofPart5areallsuccessfullycompletedforgiventrade.YESNO-ENDOFCHECKLIST-CheckEquipTag设备编号Contr.承包商Manufacturerscutsheets设备供应商提供的资料Performancedata(fancurvescoildataetc.)设备运行参数Installationandstartupmanualandplan安装和开机手册Sequencesandcontrolstrategies控制及运行逻辑顺序OMmanuals运行维护手册EquipTag—设备标号---1Manuf.2制造商3与图纸相符与提交资料相符与实际安装相符1Model2型号3与图纸相符与提交资料相符与实际安装相符Serial#1序列号与实际安装相符1Capacity2容量3与图纸相符与提交资料相符与实际安装相符1Volts/Ph/A2伏特/相/安培3与图纸相符与提交资料相符与实际安装相符1Min.OSAT2最小进风温度3与图纸相符与提交资料相符与实际安装相符CheckEquipTag设备编号,Contr.GENERALINSTALLATIONPermanentlabelsaffixed永久设备标签已粘贴Casingconditiongood:nodentsleaksdoorgasketsinstalled机组壳体状况良好无压痕,无渗漏,检修门垫圈已安装CheckEquipTag设备编号*Contr.Allcoilsarecleanandfinsareingoodcondition所有换热器盘管外观清洁并且翅片状况良好Valvesproperlytagged阀门均已标示Valvesinstalledinproperdirection阀门安装方向正确Vibrationisolationboltsloosened减震湘螺栓己松开Maintenanceaccessacceptableforunitandcomponents设备预留检修空间充足Cleanupofequipmentcompletedpercontractdocuments设备的清洁按照合同文件完成PipingandCoils管道和盘管Noleaksapparentaroundfittings.管道配件表面无泄漏Pipingsystempressuretested.管道系统试压完成Refrigerantpipingsizedaccordingtomfrsliterature制冷剂配管按照制造商的说明文件选型Refrigerantpipingingoodconditionandsuctioninsulated制冷剂配管状况良好并且吸气端保温Liquidlinesolenoidvalvelocatedatevaporatorcoilasrequired液体管路电磁阀按要求放置于蒸发器盘管Compressorliquidandsuctionlineservicevalvesopen压缩机吸气阀打开SiteChargingifapplicable制冷剂现场充注Refrigerantlinesevacuatedanddehydratedpermfrsrecommendations制冷剂管路按照制造商的要求排空并保持干燥Refrigerantchargedbystrictlyusingmfrrecommendedproceduresandaccurateinstruments.制冷剂的充注严格按照制造商推荐的程序并使用精确仪表Chargingmethodused:使用的充注方法Outsideairtemperatureduringcharging:充注处室外气温为LeakchecksmadewithleakdetectoraroundcompressorcondenserevaporatorTXVssolenoidvalvesfilterdriersandfusibleplugsandotherpipingfittings.Allleaksrepaired.使用泄露探测器检杳压缩机、冷凝器、蒸发器、膨胀阀、电磁阀、过滤干燥器及其他管路配件的制冷剂泄露情况所有的泄露都要排除CompressorandCondenser压缩机和冷凝器RefrigerantsightglassclearofbubblesifOSAT70F制冷剂视镜Moistureindicatorshowsnomoisture水分指示器显示制冷剂无水分CheckEquipTag设备编号*Contr.Correctoillevelchecksiteglassduringoperationifavailable油位准确Compressorsandpipingwereleaktestedasrequired压缩机及管路系统按要求进行了泄漏测试Adequateclearanceforairflowaroundcondenser冷凝器周围有充足空隙以利于气流流动Crankcaseheateronwhenunitisoff曲轴箱加热器在机组关闭后启动Crankcaseheaterifapplicableenergizedlongenoughforstartup曲轴箱加热器能够加热足够时间以利丁•压缩机启动ElectricalandControls电气和控制Properpowersupplyforunit机组供电正常Powerdisconnectsinplaceandlabeled电源隔离开关安装并标识Allelectricconnectionstight所有电气连接紧密Propergroundinginstalledforcomponentsandunit组件和设备接地设施安装完毕Circuitprotectionsizedandinstalledproperly电路保护选型安装适当Controlsysteminterlockshookedupandfunctional控制系统联动装置安装完毕并运行正常CheckEquipTag-设备编号Contr.Coolingandchilledwaterpump、coolingtowercollectioncorrect冷冻水泵、冷却水泵、冷却塔的连接正确Measurelinetolinevoltagephaseimbalancefor1/3ofthecompressors:Compressor1Phase:%lmbalance=100xavg.•lowest/avg.Recordincellallthreephasevoltages.Imbalancelessthan2%记录三相电压,并计算不平衡情况,三相不平衡率小于2%不平衡率=100x均值-最小值/均值Recordfullloadrunningampsforeachcompressor.ratedFLampsxsrvcfactor=Maxamps.Runninglessthanmax记录每一个压缩机满负荷运行时电机的电流0额定电流X使用系数=最大电流CheckEquipTag-设备编号Contr.冷却水环路调整记录环路流量_m3/h环路压力_MPa;记录冷却水泵运行电流和功率_A_KW冷却水环路调整记录环路流量_m3/h环路压力_MPa记录冷冻水泵运行功率_A_KWNounusualnoiseorvibrationduringoperationcondenserfancompressor运行时无异常噪音或震动冷凝器风机和压缩机Adjustthespacetemperaturecontrolstocauseacallforcooling.Verifythatcompressorstartsandthatsupplyairiscooledasexpected.调节空间温度控制使机组处于制冷状态确认空调压缩机启动并旦末端输出冷风After15minutesofoperationrecordthereadingsdata.在机组运行15分钟后,在记录读数Removethecallforcooling.Observethatcompressorcyclesoff.停止制冷运行模式,应观察到压缩机停止运行Crankcaseheaterremainsonwhenunitcyclesoffifrequired当机组运行停止后,曲轴箱加热器保持开启Startupreportcompletedwiththischecklistattached完成开机报告并附上Safetiesinstalledandsafeoperatingrangesforthisequipmentprovidedtothecommissioningagent将此设备安装的保险装置资料和安全操作范围提供给调试顾问Functionaltestproceduresforthisequipmentreviewedandapprovedbyinstallingcontractor审核此设备的功能测试程序并交由安装承包商批准Specifiedsequencesofoperationandoperatingscheduleshavebeenimplementedwithallvariationsdocumented制定的操作顺序和运行时间表已经使用,并记录所有的变更Specifiedpoint-to-pointcheckshavebeencompletedanddocumentationrecordsubmittedforthissystem其他检查已完成并将此系统的记录文件归档。